Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Rev. Bras. Saúde Mater. Infant. (Online) ; 20(2): 479-484, Apr.-June 2020. tab
Article in English | SES-SP, LILACS | ID: biblio-1136437

ABSTRACT

Abstract Objectives: to identify the main indications and reasons for discontinuing the use of the Levonorgestrel-Releasing Intrauterine System (LNG-IUS). Methods: a cross-sectional study was carried out from medical records of 327 women who used the LNG-IUS 52mg between January 2011 and December 2016 at a public hospital in the Northeast of Brazil. Results: the main indications for the use of the LNG-IUS were: contraception (32.7%), myoma/metrorrhagia (28.7%) and endometriosis/pelvic pain (22.3%). Of the 327 women, 68 (20.8%) had discontinued using the device. The most frequent reasons for discontinuation were: expulsion (9.2%), LNG-IUS expiration (3.7%), bleeding (2.4%) and pain (1.5%). Most patients had no difficulty in the insertion and did not require anesthesia/sedation. Among the 30 women who expelled the device, 17 (56.7%) had used it for metrorrhagia and myoma, 8 (26.7%) for contraception, and 5 (16.6%) for endometriosis/pelvic pain. Conclusions: the LNG-IUS is a well-accepted contraceptive method, with therapeutic applications for some gynecological conditions and a low expulsion rate.


Resumo Objetivos: identificar as principais indicações e razões para a descontinuação do uso do sistema intra-uterino liberador de levanogestrel (SIU-LNG). Métodos: foi realizado um estudo transversal a partir de prontuários de 327 mulheres que usaram o SIU-LNG 52mg entre janeiro de 2011 e dezembro de 2016 em um hospital público do Nordeste do Brasil. Resultados: as principais indicações para o uso do SIU-LNG foram: contracepção (32,7%), mioma / metrorragia (28,7%) e endometriose / dor pélvica (22,3%). Das 327 mulheres, 68 (20,8%) haviam descontinuado o uso do dispositivo. Os motivos mais frequentes de descontinuação foram: expulsão (9,2%), expiração de SIU-LNG (3,7%), sangramento (2,4%) e dor (1,5%). Conclusão: a maioria dos pacientes não teve dificuldade na inserção e não necessitou de anestesia / sedação. Entre as 30 mulheres que expulsaram o dispositivo, 17 (56,7%) o utilizaram para metrorragia e mioma, 8 (26,7%) para contracepção e 5 (16,6%) para endometriose / dor pélvica. O SIU-LNG é um método contraceptivo bem aceito, com aplicações terapêuticas para algumas condições ginecológicas e baixa taxa de expulsão.


Subject(s)
Female , Levonorgestrel/therapeutic use , Cost-Benefit Analysis , Long-Acting Reversible Contraception , Intrauterine Devices, Medicated/adverse effects , Intrauterine Devices, Medicated/statistics & numerical data , Brazil , Contraceptive Effectiveness
2.
Rev. bras. ginecol. obstet ; 42(4): 194-199, Apr. 2020. tab
Article in English | LILACS | ID: biblio-1137820

ABSTRACT

Abstract Objective Changes in bleeding patterns could influence the decisions of healthcare professionals to change the levonorgestrel-releasing intrauterine system (LNG-IUS) before 7 years of use, the recommended period of extended use. We evaluated changes in the bleeding patterns of users of the 52 mg LNG-IUS at the end of use of the first (IUS-1) and during the second device (IUS-2) use. Methods We performed an audit of the medical records of all women who used two consecutive LNG-IUSs at the Family Planning clinic. We evaluated the sociodemographic/gynecological variables, the length of use, and the bleeding patterns reported in the reference periods of 90 days before removal of the IUS-1 and at the last return in use of IUS-2. We used the McNemar test to compare bleeding patterns. Statistical significance was established at p < 0.05. Results We evaluated 301 women aged (mean ± SD) 32 (±6.1) years, with lengths of use of 68.9 (±16.8) and 20.3 (±16.7) months for the IUS-1 and IUS-2, respectively. No pregnancies were reported. Bleeding patterns varied significantly among women who used the IUS-2 for ≥ 7 months to 6 years when compared the bleeding patterns reported in IUS-1 use. Eighty-nine out of 221 (40%) women maintained amenorrhea and infrequent bleeding; 66 (30%) evolved to bleeding patterns with light flow, and 66 (30%) maintained or evolved to heavy flow patterns (p = 0.012). No differences were observed among the 80 women with ≤ 6 months of use. Conclusion Changes in bleeding patterns occur during the use of LNG-IUS and should not be decisive for the early replacement of the device.


Resumo Objetivo Variações no padrão de sangramento podem afetar a decisão de troca do sistema intrauterino de levonorgestrel (SIU-LNG) antes do período de uso estendido recomendado de 7 anos. Nós avaliamos mudanças no padrão de sangramento de usuárias ao final do uso do primeiro SIU-LNG 52 mg (SIU-1) e durante o uso do segundo dispositivo (SIU-2). Métodos Revisamos os prontuários de todas as mulheres que inseriram consecutivamente o SIU-LNG no ambulatório de Planejamento Familiar. Foram avaliadas as variáveis sociodemográficas/ginecológicas, o tempo de uso, e os padrões de sangramento relatados nos períodos de referência de 90 dias antes da remoção do SIU-1 e no último retorno em uso do SIU-2. Usamos o teste de McNemar para comparar os padrões de sangramento. A significância estatística foi estabelecida em p < 0,05. Resultados Analisamos os dados de 301 mulheres com idade (média ± desvio padrão [DP]) de 32 (±6,1) anos e tempo de uso de 68,9 (±16,8) e 20,3 (±16,7) meses para o SIU-1 e SIU-2, respectivamente. Nenhuma gravidez foi relatada. Os padrões de sangramento variaram significativamente durante o uso do SIU-2 (≥ 7 meses a 6 anos) em relação ao padrão relatado no SIU-1. Oitenta e nove das 221 (40%) mulheres mantiveram amenorreia e sangramento infrequente; 66 (30%) evoluíram para padrões de sangramento com fluxo leve e 66 (30%) mantiveram ou evoluíram para padrões de fluxo intenso (p = 0,012). Não foram observadas diferenças entre as 80 mulheres que utilizavam o SIU-2 há ≤ 6 meses. Conclusão Mudanças nos padrões de sangramento ocorrem durante o uso do LNG-IUS e não devem ser decisivas para a troca precoce do dispositivo.


Subject(s)
Humans , Female , Adult , Young Adult , Levonorgestrel/administration & dosage , Levonorgestrel/adverse effects , Levonorgestrel/therapeutic use , Contraceptive Agents, Female/administration & dosage , Contraceptive Agents, Female/adverse effects , Contraceptive Agents, Female/therapeutic use , Affective Symptoms/epidemiology , Intrauterine Devices, Medicated/adverse effects , Intrauterine Devices, Medicated/statistics & numerical data , Menstruation/physiology , Retrospective Studies , Medical Audit
3.
Rev. bras. ginecol. obstet ; 41(4): 236-241, Apr. 2019. tab
Article in English | LILACS | ID: biblio-1013605

ABSTRACT

Abstract Objective To compare sexual function and quality of life (QOL) among intrauterine contraceptive (copper-intrauterine device [Cu-IUD] or the 52-mg 20 μg/day levonorgestrel- releasing intrauterine system [LNG-IUS]) users. Methods This was part of a cross-sectional study. Women aged between 18 and 49 years old, in a heterosexual relationship, reporting sexual intercourse in the previous 4 weeks, using Cu-IUD (Group 1) or LNG-IUS (Group 2) responded to a questionnaire with sociodemographic information, to the Female Sexual Function Index (FSFI), to the World Health Organization QOL Questionnaire Abbreviated Version (WHOQOL-BREF), and to a questionnaire about the contraceptive method used. The Student t-test, the Pearson χ2 test or the Fisher exact test, and the Mann-Whitney test were used for the analysis. For the adjusted comparison, we have used the analysis of covariance (ANCOVA). A multiple regression analyzing factors related to FSFI 26.55 was done. Significance was established at p < 0.05. Results A total of 347 women in Group 1 (mean age of 32.3 ± 7.5 years old) and of 298 in Group 2 (mean age of 32.7 ± 6.4 years old) completed the questionnaires.Most women had ≥ 8 years of schooling, were in amonogamous relationship, and had had ≤ 2 pregnancies. A total of 122 Cu-IUD and of 87 LNG-IUS users scored ≤ 26.55 on the FSFI. Significant lower scores in physical, environmental, and overall QOL domains in the WHOQOL-BREF questionnaire were found in Group 1. More women using the Cu- IUD were not satisfied with the method. Conclusion We did not find significant differences in sexual function; there was a lower score in some domains of QOL among women who used the Cu-IUD. It was not possible to ensure that those differences were related to the contraceptive method.


Resumo Objetivo Comparar a função sexual e a qualidade de vida (QV) entre usuárias de contraceptivos intrauterinos (dispositivo intrauterino com cobre [DIU-cobre] ou sistema intrauterino liberador de levonorgestrel [SIU-LNG 52 mg 20 μg/dia]. Métodos O presente estudo foi parte de um estudo de corte transversal. Mulheres com idades entre 18 e 49 anos, em relacionamento heterossexual, relatando relação sexual nas 4 semanas anteriores, utilizando DIU-cobre (Grupo 1) ou SIU-LNG (Grupo 2) responderam ao questionário com informações sociodemográficas, ao Índice de Função Sexual Feminino (IFSF), ao Questionário de QV da Organização Mundial de Saúde, versão abreviada (WHOQOL-BREF, na sigla eminglês), e a umquestionário sobre ométodo contraceptivo utilizado criado para o presente estudo. Os testes t de Student, o teste χ2 de Pearson, o teste exato de Fisher e o teste de Mann-Whitney foram utilizados. A análise de covariância (ANCOVA) foi utilizada para a comparação ajustada. Foi realizada a análise de regressão logística multivariada analisando fatores associados ao IFSF ≤ 26.55. O nível de significância foi p < 0.05. Resultados Um total de 347 mulheres no Grupo 1 (idade média 32,3 ± 7,5 anos) e de 298 no Grupo 2 (idade média 32,7 ± 6,4 anos) completaram os questionários. A maioria das mulheres relatou ≥ 8 anos de escolaridade, estava emrelaçãomonogâmica e teve ≤ 2 gestações. Um total de 122 e de 87 usuárias do DIU-cobre e do SIU-LNG, respectivamente, pontuaram ≤ 26,55 no IFSF. Pontuações significativamente menores nos domínios físico, meio-ambiente e QV geral no WHOQOL-BREF foram encontrados no Grupo 1. Mais mulheres do Grupo 1 estavam insatisfeitas com o método. Conclusão Não encontramos diferenças na função sexual, entretanto havia menores pontuações em certos domínios da QV entre as usuárias do DIU-cobre. Não foi possível afirmar relação dessas diferenças com os métodos.


Subject(s)
Humans , Female , Adolescent , Adult , Young Adult , Quality of Life , Sexual Behavior , Intrauterine Devices/statistics & numerical data , Brazil , Cross-Sectional Studies , Surveys and Questionnaires , Cohort Studies , Levonorgestrel , Intrauterine Devices, Medicated/statistics & numerical data , Intrauterine Devices, Copper/statistics & numerical data , Middle Aged
4.
Bol. Centro Biol. Reprod ; 17: 51-9, 1998. tab
Article in Portuguese | LILACS | ID: lil-247713

ABSTRACT

Atualizaçäo dos dados da pesquisa sobre o dispositivo intrauterino (DIU) liberador de 20 mcg/dia de levonorgestrel (DIU-LNG) comparado com o DIU de cobre, TCu 380A, em estudo multicêntrico da Organizaçäo undial da Saúde (OMS), desenvolvida na Maternidade Therezinha de Jesús e no CEPECS, para o Centro de Biologia da Reproduçäo da UFJF. Em 200 mulheres, foram avaliados os índices de continuaçäo, os abandonos, os efeitos colaterais e outros eventos ao longo de 4 anos com 3972 meses/mulher para o TCu 380A e com 3544 meses/mulher de observaçäo com o DIU-LNG. Neste período houve 21 descontinuaçöes com o TCu 380A e 35 com o DIU-LNG. Considerando-se que 19 usuárias pediram para retirar o DIU porque queriam nova gestaçäo o índice de continuaçäo com os dois DIUs é bastante aceitável (79 por cento com o DIU de cobre e 65 por cento com o DIU-LNG). Os efeitos colaterais mais frequentes com o uso do DIU-LNG foram o sangramento irregular e a amenorréia, mas apenas 6 tiveram seu DIU removido por esta causa, as demais aceitaram continuar. Näo houve neste período nenhuma gravidez, e apenas 4 pacientes foram perdidas no seguimento. O DIU-LNG por sua alta eficácia e poucos efeitos colaterais é uma promessa de um novo e excepcional método contraceptivo.


Subject(s)
Humans , Intrauterine Devices, Medicated/statistics & numerical data , Dimethylpolysiloxanes/therapeutic use , Intrauterine Devices, Copper/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL